Thermostat, thermal control, or temperature limiter
Contact form: Single pole single throw, open on temperature rise, or double-throw
Rated load:
20 A 250 VAC (resistive load)
5 A 250 VAC (inductive load)
10 A 400 VAC (resistive load)
1 A 400 VAC (inductive load)
Operating temperature range:
-10 to 80°C, 4 to 40°C, 0 to 60°C, 0 to 120°C, 30 to 90°C,
30 to 110°C, 30 to 120°C, 30 to 150°C, 50 to 200°C, 50 to 220°C,
50 to 300°C, 50 to 320°C, 60 to 400°C
Temperature of switch head: up to 150°C
Standard length of capillary of 900 mm or customer specific
Material of sensor system: copper or stainless steel
Bulb diameter (standard):
Copper: 3.1; 4; 5; 6; or 9.5 mm
Stainless steel: 3;4; 5; or 6 mm
Optional: customer specific
Sensor length is customizable depending on material, diameter, and adjustable temperature range
Diverse isolation tube materials (i.e. PVC or silicone-fiber glass) for the capillary and brackets
Multiple options for adjustment stems and mounting brackets
Large variety of accessories: knobs, bezels, pocket- and compression-fittings
Suitable for class I and II controls
Approvals: ENEC 03 (EN 60 730-1 and EN 60 730-2-9), UL