• TU.RM FS

TU.RM FS

  • Thermal cut-out with fail-safe sensing system (Type 2K in accordance to EN 60 730)
    Contact form: Single pole single throw, open on temperature rise, manual reset
    Contact rating (per pole):
    16 A 250 VAC (resistive load)
    5 A 250 VAC (inductive load)
    Calibration OFF temperature can be set from +40°C to +335°C
    Calibration factory pre-set
  • Max. switch head temperature: +150°C
  • Sensing system:
    Standard length of capillary 900 mm or customer specific.
    Material: Copper or stainless steel.
    Bulb diameter: 3, 4, 5 or 6 mm.
    Sensor length is customizable depending on material, diameter, and adjustable temperature range.
    Diverse isolation tube materials (i.e. PVC or silicone-fiber glass) for the capillary tube.
  • Approvals: ENEC in accordance to EN 60 730-1 und EN 60 730-2-9