Pipe-Mount Temperature Limiter with Capillary Sensor
Thermal cut-out (Type 2B in accordance to EN 60 730)
Incorporated temperature limiter TS-RM series
Contact form: Single pole single throw, open on temperature rise, or double-throw, manual reset
Contact rating (open on rise switch):
16 A 250 VAC (resistive load)
5 A 250 VAC (inductive load)
Contact rating (open on rise switch):
0,5 A 250 VAC (resistive load)
Calibration OFF temperature can be set from +40°C to +110°C
Calibration factory pre-set
Plastic case with thermowell and cable gland
Internal termination: Quick connect terminals 6,3×0,8 mm or screw terminals (Standard).
Max. switch head temperature: 80°C,
Protection Class: IP40,
Colour of case: White, brown or orange,
Colour of cap: White or black,
Assembly with fitting spring to pipes with a diameter of 3/4″ to 3″.
Sensing Element:
Material: Stainless steel,
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9)